CVE-2017-7901

Description

A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.

Severity
HIGH
CVSS v3
8.6
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H · source nvd
Exploit chance (EPSS)
9.046%
chance of exploitation in the next 30 days
higher than 95.4% of scored CVEs · 2026-11-17
CISA KEV
Not listed
Public exploit code
None public
Exploit references (NVD and CNA): 0
Metasploit modules: 0
Nuclei templates: 0

Weakness

Timeline

  1. 2017-06-30Published by the CNA02:35 UTC

The timeline shows what already happened. To be told when this CVE changes next, watch it from the API.

Affected products

VendorProduct
rockwellautomation1763-l16awa_series_a
rockwellautomation1763-l16awa_series_b
rockwellautomation1763-l16bbb_series_a
rockwellautomation1763-l16bbb_series_b
rockwellautomation1763-l16bwa_series_a
rockwellautomation1763-l16bwa_series_b
rockwellautomation1763-l16dwd_series_a
rockwellautomation1763-l16dwd_series_b
rockwellautomation1766-l32awa_series_a
rockwellautomation1766-l32awa_series_b
rockwellautomation1766-l32awaa_series_a
rockwellautomation1766-l32awaa_series_b
rockwellautomation1766-l32bwa_series_a
rockwellautomation1766-l32bwa_series_b
rockwellautomation1766-l32bwaa_series_a
rockwellautomation1766-l32bwaa_series_b
rockwellautomation1766-l32bxb_series_a
rockwellautomation1766-l32bxb_series_b
rockwellautomation1766-l32bxba_series_a
rockwellautomation1766-l32bxba_series_b

References

Get more CVE data from the API.

Free without a key or signup. Pro adds monitoring and higher limits: pricing.