CVE-2026-116783

Description

FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.2, udptl_rx_packet() used a peer-controlled FEC entry count directly to fill five-entry FEC arrays in a mod_spandsp T.38 session. A larger count wrote sender-controlled error-recovery data beyond those arrays and persisted the oversized count for a later reconstruction pass. Any peer able to deliver UDPTL to an established T.38 fax session can reach the parser, including deployments using fax applications or a T.38 gateway. The memory corruption can crash FreeSWITCH and end every active call, although remote code execution has not been demonstrated. This issue is fixed in version 1.11.2.

Severity
HIGH
CVSS v3
8.2
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H · source cna
Exploit chance (EPSS)
0.618%
chance of exploitation in the next 30 days
higher than 50.4% of scored CVEs · 2026-11-18
CISA KEV
Not listed
Public exploit code
None public
Exploit references (NVD and CNA): 0
Metasploit modules: 0
Nuclei templates: 0

Weakness

CISA SSVC decision points

Exploitationnone
Automatableyes
Technical impactpartial
Scored2026-11-09

Timeline

  1. 2026-11-05Published by the CNA19:41 UTC
  2. 2026-11-09CISA SSVC decision recorded4 days after publication

The timeline shows what already happened. To be told when this CVE changes next, watch it from the API.

Affected products

Products listed as vulnerable. Upgrade to the version under "Fixed in", or a later one.

ProductVulnerable versionsFixed in
freeswitch freeswitchbefore 1.11.2fixed in 1.11.21.11.2
signalwire freeswitch

Products and versions as NVD and the vendor that published the CVE list them.

References

Get more CVE data from the API.

Free without a key or signup. Pro adds monitoring and higher limits: pricing.