CVE-2026-124312

Description

Fraunhofer HHI VVdeC through 3.2.1 contains a heap out-of-bounds read vulnerability that allows attackers to crash the decoder by supplying a collocated picture of different resolution. Attackers can craft a VVC bitstream enabling TMVP with a smaller collocated reference picture, causing getColInfo to read past the colMotion allocation when error concealment is enabled.

Severity
MEDIUM
CVSS v3
4.7
CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H · source cna
CVSS v4
5.7
CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N · source cna
Exploit chance (EPSS)
0.116%
chance of exploitation in the next 30 days
higher than 1.6% of scored CVEs · 2026-11-18
CISA KEV
Not listed
Public exploit code
None public
Exploit references (NVD and CNA): 0
Metasploit modules: 0
Nuclei templates: 0

Weakness

CISA SSVC decision points

Exploitationpoc
Automatableno
Technical impactpartial
Scored2026-11-09

Timeline

  1. 2026-11-07Published by the CNA14:17 UTC
  2. 2026-11-09CISA SSVC decision recorded2 days after publication

The timeline shows what already happened. To be told when this CVE changes next, watch it from the API.

Affected products

Products listed as vulnerable. Upgrade to the version under "Fixed in", or a later one.

ProductVulnerable versionsFixed in
fraunhoferhhi vvdecfrom 0 through 3.2.1no fix listednot listed

Products and versions as NVD and the vendor that published the CVE list them.

References

Get more CVE data from the API.

Free without a key or signup. Pro adds monitoring and higher limits: pricing.

Sources